Images are representations only.

ProTalk Cv3

Brand: Barnett ProTalk
Please creat quote for pricing
The ProTalk Cv3 provides advanced notification of potentially problematic situations with your site and/or equipment. Capable of monitoring both digital and analog inputs, the ProTalk Cv3 provides versatility and flexibility. The unit is integrated with an LTE cellular module allowing for installation in remote sites. Alarm notifications can be sent via phone, text, email, radio or PA System. Remote alarm acknowledgment, system interrogation and relay control is possible via phone and text.
The ProTalk Cv3 is a device used to notify an end user of alarm conditions at an unattended local or remote site.

Alarm conditions are defined by the user and can include such things as pump failures, tank levels and pressure changes. Inputs can be defined as alarming or monitor only, allowing you to define which changes are most critical and require immediate notification.
When an alarm condition occurs, the ProTalk Cv3 will announce the alarm using the internal cellular module. The unit will continue to call out using the predefined directory until such time as the alarm is acknowledged.
The B1277 ProTalk Cv3 is very versatile and can be programmed to perform many more functions at the discretion of the user. It can:
  • announce alarms over telephone, text, radio, PA, email or any combination thereof.
  • be programmed to send coded tones along with the voice messages to activate such devices as radio pagers, relay and annunciator panels.
  • perform remote control functions using the 4 relay outputs automatically or by receiving user defined DTMF codes.
  • use up to 4 alarm groups and shifts to create custom directories based on common alarms or time of day.
  • email a daily activity summary report to notify you of all recorded activity
  • email and/or text notifications when alarms are announced, cleared and/or acknowledged (for informational purposes only).
  • email, text and/or phone regular status reports including alarm status and enabled point values
  • define security levels for incoming calls and text messages.
  • require an access code for phone or text access to programming.
  • interact with you in French (limitations apply, contact us for details).
  • be installed in hazardous locations requiring Class I, Div 2 rating.
  • function in extreme temperatures of -40°C to +60°C (-40°F to 140°F).
The ProTalk Cv3 is the industry standard in cellular alarm dialing and SMS notification and is designed to operate in urban, rural and remote sites across North America.
Features
Supported Cellular Networks:
  • Canada (Telus, Bell, Rogers, SaskTel)
  • USA (Verizon)
Display
  • Indicator LED's and connector markings
Alarm Inputs
  • 10 inputs; configured as Digital or Analog (0-5 VDC, 0-30 VDC and 4 - 20 mA loops)
  • 2 Internal Alarm Points (Power Fail and System Alarm)
  • Plug-in screw terminal block accepts AWG 26 to 12 wire
Relay Outputs
  • Contact Rating: 2 A / 30 VDC
  • Plug-in screw terminal block accepts AWG 26 to 12 wire
  • 2 programmable contact terminals
Program Ports
  • USB - Equivalent functions as DB9
  • Telset - RJ11 connects to DTMF capable phone for voice recording and programming
The ProTalk Cv3 provides advanced notification of potentially problematic situations with your site and/or equipment. Capable of monitoring both digital and analog inputs, the ProTalk Cv3 provides versatility and flexibility. The unit is integrated with an LTE cellular module allowing for installation in remote sites. Alarm notifications can be sent via phone, text, email, radio or PA System. Remote alarm acknowledgment, system interrogation and relay control is possible via phone and text.
The ProTalk Cv3 is a device used to notify an end user of alarm conditions at an unattended local or remote site.

Alarm conditions are defined by the user and can include such things as pump failures, tank levels and pressure changes. Inputs can be defined as alarming or monitor only, allowing you to define which changes are most critical and require immediate notification.
When an alarm condition occurs, the ProTalk Cv3 will announce the alarm using the internal cellular module. The unit will continue to call out using the predefined directory until such time as the alarm is acknowledged.
The B1277 ProTalk Cv3 is very versatile and can be programmed to perform many more functions at the discretion of the user. It can:
  • announce alarms over telephone, text, radio, PA, email or any combination thereof.
  • be programmed to send coded tones along with the voice messages to activate such devices as radio pagers, relay and annunciator panels.
  • perform remote control functions using the 4 relay outputs automatically or by receiving user defined DTMF codes.
  • use up to 4 alarm groups and shifts to create custom directories based on common alarms or time of day.
  • email a daily activity summary report to notify you of all recorded activity
  • email and/or text notifications when alarms are announced, cleared and/or acknowledged (for informational purposes only).
  • email, text and/or phone regular status reports including alarm status and enabled point values
  • define security levels for incoming calls and text messages.
  • require an access code for phone or text access to programming.
  • interact with you in French (limitations apply, contact us for details).
  • be installed in hazardous locations requiring Class I, Div 2 rating.
  • function in extreme temperatures of -40°C to +60°C (-40°F to 140°F).
The ProTalk Cv3 is the industry standard in cellular alarm dialing and SMS notification and is designed to operate in urban, rural and remote sites across North America.
Features
Supported Cellular Networks:
  • Canada (Telus, Bell, Rogers, SaskTel)
  • USA (Verizon)
Display
  • Indicator LED's and connector markings
Alarm Inputs
  • 10 inputs; configured as Digital or Analog (0-5 VDC, 0-30 VDC and 4 - 20 mA loops)
  • 2 Internal Alarm Points (Power Fail and System Alarm)
  • Plug-in screw terminal block accepts AWG 26 to 12 wire
Relay Outputs
  • Contact Rating: 2 A / 30 VDC
  • Plug-in screw terminal block accepts AWG 26 to 12 wire
  • 2 programmable contact terminals
Program Ports
  • USB - Equivalent functions as DB9
  • Telset - RJ11 connects to DTMF capable phone for voice recording and programming
Models matching criteria: 2
Cv3 Auto Dialer with Internal Battery backup
3 - 4 weeks
Does not ship to OH, United States
Cv3 Auto Dialer
3 - 4 weeks
Does not ship to OH, United States